Fired heater design multiple choice test.
Conditions:
1. 45 questions, 1-hour time
2. No negative point
3. Once “FINISH” button is pressed the answers cannot be changed.

Fired heater design project.
Conditions:
1. A VC fired heater shall be designed for EOR case based on below datasheet.
2. Solution shall be submitted to:
E-Mail: f.naghsh@gmail.com
Subject format: Gastesh – Engineer name
3. The project shall be submitted no later than Saturday 23rd of Tir 1403

 
QUIZ START

Results

#1. Which one is not a safety concern in direct fired heaters?

#2. Which one is caused by the excessive heat recovery in mechanical draft heaters?

#3. Which one is not an architecture to control combustion air on natural draft direct fired heaters?

#4. Chemically bonded plastics are from which group of refractories?

#5. For single-fired, box-type, floor-fired heaters with sidewall tubes only, what is the maximum height to width ratio?

#6. Burning which stream generates fuel NOx?

#7. What the maximum apex angle of transitions in cylindrica stack diameters? (degrees)

#8. We intend to post-treat a flue gas using SCR system. Which reagent is NOT used for this purpose?

#9. What is tramp air?

#10. What is another name for arch?

#11. Which one is not a mechanism for air and fuel mixing in a burner?

#12. What is the difference between combustion and oxidation?

#13. What is the minimum thickness of end tube sheets required by API-560?

#14. Where is a heater draft controlled as a minimum?

#15. Assume a natural draft heater. Which cause & effect is necessarily correct?

#16. How much pressure of the total airside pressure drop should be used at the throat of burner as per API-560?

#17. Why are burners staged?

#18. Which one is a reactor heater?

#19. Which one is a more acceptable reason to choose a fired heater over a heat exchanger in a process?

#20. If not previously completely dried out to operating temperature, what is the maximum heating rate of castable refractory as per API-560? (deg.C/h)

#21. Which liquid fuel needs atomization but not preheating?

#22. Which heater type is normally economical to be used for lowest duties (up to 5 MW)?

#23. Which one is the flame color wave length color in direct relation with? (Note: yellow has a higher wave length than blue in visible spectrum)

#24. Which is the radiant tubes manufacturing technology?

#25. Which pressure drops does NOT induced fan make up in a well-designed vertical cylindrical heater?

#26. What is the result of (HHV-LHV)?

#27. Which one causes hot spot in a properly designed heater?

#28. How can we mitigate effects of vanadium ashes generation in fuel gas?

#29. We intend to burn a waste gas stream. What is the suitable equipment for this purpose?

#30. Which liquid fuel vaporizes when it comes into contact with a hot surface?

#31. Assume we have 250 deg.C process fluid with the fuel having high degrees of sulphur. Which choice of material is better for radiant tubes?

#32. Why are heaters designed for negative pressures?

#33. Which one is better defined as an air preheater type?

#34. How much is the limitation of radiant floor firing density? (Btu/h/ft2)

#35. What is the range of overall thermal efficiency of a mechanical draft direct fired heater?

#36. Which burner type has a danger of flash back?

#37. Increase in average allowable radiant heat flux:

#38. What is the allowable travel time range from damper fully open to damper fully closed? (seconds)

#39. Which one is not correct? The higher the API degree gravity, ….

#40. Which one does NOT the flame speed depend on?

#41. 21 % excess air equals how much excess O2 in combustion products?

#42. Assume we have 900 deg.C as the exit temperature of process fluid from radiant section. The fluid in preheated in convection section up to 350 deg.C. If nickel alloy is selected as the radiant tube material, what is a good choice for shield tubes?

#43. What is main usage of strakes on stacks?

#44. How much excess air is needed for natural draft heaters with oil as the primary fuel?

#45. Which one is not considered a pollutant in heater design?

Previous
Finish